OLTC / OCTC
for Power Transformers

OLTC / OCTC for Power Transformers

On-load and deenergized tap-changers for power transformers

Request for Brochure
On-load tap-changers (OLTC) and deenergized tap-changers (OCTC) are indispensable in regulating power transformers used in electrical energy networks and industrial applications. With over 50 years of experience, EMR is a leading player today in the tap changer market. With a comprehensive range of on-load tap changers for nearly all network applications, EMR is the trusted partner to Utilities, Consultants and Transformer Industry in and outside of India.
  • v type
  • m Type
  • d type
  • octc

V TYPE

COMPACT & ECONOMICAL

Current rating up to 500 A & Voltage up to 132 kV (Y/D).

Special designs are avilable for 250 and 400 A on request.

Both star and delta applications are available.

Step voltage is 1500 Volts.

In-built selector switch model.

Bi-directional power flow.

Very compact dimensional arrangement.

Easy removal of diverter switch inserts, making it maintenance friendly.

Linear version is available up to 14 positions.

Up to 27 positions are available with the pre-selector arrangement.

No barrier board problems.

Electrical parameters

TYPE

Current Rating (A)

Voltage Variants

BIL kV/kVp

Max. Rated Step Voltage (Volts)

Max. Operating Position

Three Pole

Single Pole

Voltage Level (kV)

Vector

Linear

Pre-Selector

V TYPE

200, 350 & 500

350 & 700A*

40

Y, D

70/200

1500

14 & 18

27

76

140/350

123/76

230/550

M TYPE

MODERN, SUPERIOR & VERSATILE

Used in up to 765 kV Transformers

Three-pole design for neutral application at 350A, 500A & 600A rating for three-phase Y-connected windings.

Single-pole design at 350A, 500A, 600A, 800A, 1200A, 1500A and 1800A ratings for auto connected windings or single-phase transformers.

Available with ±9, ±11, ±13, ±15, ±17 steps.

Special design available with 700 A, 3 Phase & 2100 & 2400 A, Single Phase*

Available on both star and delta-insulation to ground, and tap selector size can be selected independently of one another.

Convenient for bell-type tank installations.

Additional device for potential tie-in of tap winding, during change-over operation of the change-over selector.

High-speed transition resistor-type diverter switch with arc extinction at first current zero.

Diverter switch uses sharp-action mechanics by energy accumulator mounted directly on diverter switch.

Minimum possible tap selector dimension because four avilable sizes ensure matched inpulse voltage withstandability.

Radial dimensions of the tap selector are reduced by special shaping of all parts on high potential. Distances between tap selector bars determined by actual voltage stress.

Optimised integration of the change-over selector into the fine selector contact circle.

Long life and reduced maintenance - rapid tap change operation. Low thermal stress on the transition resistors.

Special contacts for alternative oil application.

Simple tap selector design, effective contact cooling,
high short-circuit withstandability.

Optimised integration of the change-over selector into the fine selector contact circle.

Long life and reduced maintenance - rapid tap change operation. Low thermal stress on the transition resistors.

Special contacts for alternative insulating liquids on request

Simple tap selector design, effective contact cooling,
high short-circuit withstandability.

Electrical parameters

TYPE

Current Rating (A)

Voltage Variants

BIL kV/kVp

Max. Rated Step Voltage (Volts)

Max. Operating Position

Three Pole

Single Pole

Voltage Level (kV)

Vector

Linear

Pre-Selector

M TYPE

350, 500, 600 & 700*

350, 500, 600, 800, 1200, 1500, 1800, 2100* & 2400*

72.5

Y, D

140/350

3300

22

35

123

Y, D

230/550

170

Y

325/750

245

Y

395/950

300

Y

460/1050

D TYPE

HEAVY DUTY & TIME TESTED

Type ‘D’ Model is a true testimony of EMR’s time tested credentials for superior tap changer technology. This model is in successful service since 1975 catering to normal network applications and to demanding heavy duty furnace applications.

Current rating up to 500 A with 3-pole & up to 1500 A* with 1 pole.

Linear version applicable up to 18 position.

Special design is available for 300 A.

Voltage class up to 220 kV Class.

Both star and delta applications are available.

Maximum step voltage up to 2500 Volts.

Separate diverter and selector model.

Bi-directional power flow.

Up to 35 positions available for pre-selector arrangements.

Over 1500 in-tank installation in ultra heavy duty applications which involve 500 operations per day.

Electrical parameters

TYPE

Current Rating (A)

Voltage Variants

BIL kV/kVp

Max. Rated Step Voltage (Volts)

Max. Operating Position

Three Pole

Single Pole

Voltage Level (kV)

Vector

Linear

Pre-Selector

D TYPE

200, 400 & 500

200, 400, 600*, 800*, 1200* & 1500*

36

Y, D

75/200

2500

18

35

60

140/350

110

230/550

150

325/750

OCTC

High speed snap action design.

Design occording IEC 60214-1.

Single and three phase Off-Circuit tap-changers for up to 4000 A rated through-current*

Rated insulation on level up to Um=300kV is possible.

Higher values possible as special design.

High safty is ensured with special switching.

Compact, most roubst and state-of-the art design.

Modular concept, which allows to manufacture as per the required specification.

Optimized field design through smooth surface, soft edges and use of innovative materials.

Possible driveType: - Manual drive - Motor drive

Hands on Wheel

Easy Installation in the transformers

Electrical parameters of OCTC

TYPE

Current Rating (A)

Voltage Variants

BIL kV/kVp

Max. Rated Step Voltage (Volts)

Max. Operating Position

Three Pole

Single Pole

Voltage Level (kV)

Vector

Linear

Pre-Selector

OCTC

350, 500 & 600

350, 500, 600, 800, 1000, 1200, 1500, 1800 & 2000

72.5

Y, D

140/350

6600

9

NA

123

230/550

170

325/750

245

Y

395/950

300

460/1050

*on request, please contact us
Spares_1

For superior performance and increased life use genuine spares from EMR

Training

Training

EMR offers training on all aspects of our various product offerings

Retrofit
Increase the life expectancy of transformers with retrofit solutions from EMR
We provide a wide range of spares and accessories for your mission critical equipments. We are committed to provide best customer services to ensuer smooth operations at all times

Our Clients

Scroll to Top

Fill in the Information to Download the Operating Instructions / Brochure

*mandatory

Fill in the Information to Download the Operating Instructions / Brochure

*mandatory

Fill in the Information to Download the Operating Instructions / Brochure

*mandatory

Fill in the Information to Download the Operating Instructions / Brochure

*mandatory

Fill in the Information to Download the Operating Instructions / Brochure

*mandatory

Fill in the Information to Download the Operating Instructions / Brochure

*mandatory