OLTC/OCTCs
for Distribution
Transformers

OLTC/OCTCs for Distribution Transformers

DVAC & L TYPE

Request for Brochure
The Dvac model is an oil free dry type on-load tap-changer for uninterrupted voltage adjustment on dry-type transformers under load. It is designed as a single-phase module directly assigned to the transformer limb.EMR’s L type tap-changer is a compact and innovative design for on-load tap-changing applications, particularly suited for 33/11 KV transformers.
  • DVac
  • l type

DRY VACUUM TYPE (Dvac)

MODERN, SUPERIOR & VERSATILE

The DVac has a maximum rated through-current of 500A and a max. rated step voltage of 900V for linear voltage adjustment in nine to seventeen operating positions.

Each DVac module contains a tap selector and diverter switch for high-speed resistor type tap change operation in a compact design.

The movable tap selector contact system and the diverter switch, with the spring-energy accumulator are driven by a screw spindle.

Vacuum Interrupters are used as the switching elements which guarantees maintenance free operation and prolonged life

It contains all the devices required for local and remote control, for the remote display of operating positions as well as the electrical and mechanical end position limits.

As standard equipment, a motor drive unit which functions according to the step-by-step switching principle is provided to mechanically operate the on-load tap-changer.

Its protective housing makes the motor drive unit suitable for outdoor installation, and in case of a dry-type transformer in encapsulated design it can be mounted outside the transformer tank.

Vacuum-interrupters, based on the proven vacuum technology, are used as load-switching contact elements. They guarantee excellent electrical and mechanical properties over an extremely long lifespan.

Its protective housing makes the motor drive unit suitable for outdoor installation, and in case of a dry-type transformer in encapsulated design it can be mounted outside the transformer tank.

Vacuum-interrupters, based on the proven vacuum technology, are used as load-switching contact elements. They guarantee excellent electrical and mechanical properties over an extremely long lifespan.

Electrical parameters

TYPE

Current Rating (A)

Voltage Variants

BIL kV/kVp

Max. Rated Step Voltage (Volts)

Max. Operating Position

Three Pole

Single Pole

Voltage Level (kV)

Vector

Linear

DVAC

200, 300 & 500

200, 300 & 500

11

Y, D

85/200

900

17

33

Y, D

900

L TYPE

Integrated drive mechanism.

Designed for 500,000 operations.

No barrier board required.

No huge sealing area required, hence leak free.

Transformer size becomes very slim.

No conservator required and hence no piping costs.

Between 50,000 operations, no maintenance is needed.

Total freedom from menace of barrier board related problem.

Only half an hour time required for the inspection of OLTC.

Electrical parameters

TYPE

Current Rating (A)

Voltage Variants

BIL kV/kVp

Max. Rated Step Voltage (Volts)

Max. Operating Position

Single Pole

Voltage Level (kV)

Vector

Linear

Pre-Selector

L TYPE

200

11, 22 & 33

Y, D

80/250

825

9

17

Spares_1

For superior performance and increased life use genuine spares from EMR

Training

Training

EMR offers training on all aspects of our various product offerings

Retrofit
Increase the life expectancy of transformers with retrofit solutions from EMR
We provide a wide range of spares and accessories for your mission critical equipments. We are committed to provide best customer services to ensuer smooth operations at all times

Our Clients

Scroll to Top

Fill in the Information to Download the Operating Instructions / Brochure

*mandatory

Fill in the Information to Download the Operating Instructions / Brochure

*mandatory

Fill in the Information to Download the Operating Instructions / Brochure

*mandatory

Fill in the Information to Download the Operating Instructions / Brochure

*mandatory

Fill in the Information to Download the Operating Instructions / Brochure

*mandatory

Fill in the Information to Download the Operating Instructions / Brochure

*mandatory

Fill in the Information to Download the Operating Instructions / Brochure

*mandatory