on-load tap changer manufacturer for global markets

EMR’s Global Range: OLTCs and Transformer Protection for International Markets

Built in India, Trusted Across Grids

A tap changer is the one moving part a transformer cannot do without. It switches under load thousands of times a year, and when it fails, the whole transformer goes offline. For utilities and transformer manufacturers outside India, choosing an OLTC supplier is therefore a decision about the next 25 years of grid reliability, not just a purchase.

EMR has designed and manufactured on-load tap changers since 1974. Over 50 years, that experience has been distilled into a focused range offered as standard to international markets: four tap changers and one transformer protection system. Each covers a clear application, from compact grid transformers to 765 kV transmission units.

Here is what the global range includes, and how to pick the right product for your transformer.

The EMR Global Range at a Glance

ProductTransformer typeKey ratingsBest for
Type M OLTCPower350–2,400 A, up to 765 kV, up to 35 positionsTransmission and large grid transformers
Type V OLTCPowerUp to 500 A, up to 132 kV, 1,500 V stepCompact, economical grid transformers
V-VAC OLTCPower400 A, 1,300 V step, up to 19 positionsUp to ~70 MVA, 132 kV, low-maintenance sites
Type L 33 kV OLTCDistributionMax 200 A, max 17 taps33 kV distribution networks
NITPSPower and distribution50 ms activationFire and explosion protection for critical assets

For Power Transformers

Type M: the high-capacity workhorse. Type M is EMR’s most powerful tap changer, used in transformers up to 765 kV. It is available in three-pole versions from 350 to 700 A and single-pole versions from 350 to 2,400 A, with step voltages up to 3,300 V and up to 35 operating positions. A high-speed diverter switch extinguishes the arc at the first current zero, keeping thermal stress on transition resistors low. Special contacts also suit alternative insulating liquids, which matters as more utilities move to ester oils.

Type V: compact and economical. Type V combines the diverter and selector in one compact unit with an in-built selector switch. It handles up to 500 A (with 350 A and 700 A single-pole options) on transformers up to 132 kV, and supports bi-directional power flow. That makes it a strong fit for grids with growing renewable injection, where power can flow both ways.

V-VAC: vacuum switching, no arcing in oil. V-VAC uses vacuum interrupters, so no switching arcs form in the transformer’s insulating oil. The result is cleaner DGA readings, no need for an oil filtration system, and a rated maintenance interval of 300,000 operations. It is rated at 400 A with a 1,300 V step voltage and up to 19 positions, and suits power transformers up to about 70 MVA on 132 kV systems.

For Distribution Transformers

Type L 33 kV: sealed, motorised and low-maintenance. Type L is a compact, three-phase OLTC with an integrated motor drive, designed for 33 kV distribution transformers. It handles up to 200 A and 17 tap positions. The sealed design needs no conservator or barrier board, which means slimmer transformers, fewer leak points and less piping. It is designed for 500,000 operations and needs no maintenance for the first 50,000, while an inspection takes about 30 minutes.

Protection for Both: NITPS

NITPS (Nitrogen Injection Transformer Protection System) is EMR’s answer to transformer fire and tank explosion. A patented Early Arc Detection sensor identifies arcing inside the tank. Within 50 milliseconds, the system injects nitrogen to displace oxygen, limit pressure build-up and stop a fault from becoming a fire. Cloud-based 24×7 surveillance lets asset owners watch every installed unit remotely. For critical grid, industrial and generation transformers, it protects not only the asset but everything around it.

How to Choose the Right Product

  • Voltage above 132 kV or current above 700 A: Type M.
  • Grid transformer up to 132 kV, budget-sensitive: Type V.
  • Up to ~70 MVA where maintenance access is limited: V-VAC.
  • 33 kV distribution with frequent tap changes: Type L 33 kV.
  • Any critical transformer where a fire would be unacceptable: add NITPS.

Every tap changer can be paired with EMR’s Motor Drive Unit, which supports SCADA connection over IEC 61850 and IEC 60870-5-101/104.

Need a Product Not Listed Here?

EMR’s full portfolio is wider than the global range. Products such as Type XT, Dry-VAC, Type L 11 kV, DETCs, the Smart Breather and the Oil Filtration Unit are standard in India and available for other markets on request. If your project needs one of them, the EMR team will review your specification and confirm availability.

The Bottom Line

The EMR global range covers the voltage regulation needs of most utilities and transformer builders: Type M for high voltage, Type V and V-VAC for grid transformers, Type L for 33 kV distribution, and NITPS to protect them all. Each one is backed by 50 years of OLTC design, in-house testing and genuine spares support.

Frequently Asked Questions

1. Which EMR products are available outside India? Type M, Type V, V-VAC and Type L 33 kV tap changers, plus the NITPS fire protection system, are offered as standard to global markets. Other products are available on request.

2. What is the highest voltage EMR’s tap changers support? Type M is used in transformers up to 765 kV, with single-pole versions up to 2,400 A.

3. What is the advantage of a vacuum tap changer like V-VAC? Vacuum interrupters keep switching arcs out of the oil. That means cleaner DGA results, no OLTC oil filtration and a 300,000-operation maintenance interval.

4. Can EMR’s OLTCs connect to SCADA? Yes. EMR’s Motor Drive Units support SCADA/DCS connection over IEC 61850 and IEC 60870-5-101/104, with an integrated web server.

5. Can I order an EMR product that is not in the global range? Yes. Products outside the global range are available on request. Share your transformer specification with the EMR team to confirm.

CTA: Planning a transformer project outside India? Download the brochure or write to emr@emr.global to find the right EMR tap changer for your specification.

Scroll to Top

Thank You!

Fill in the Information to Download Brochure

*mandatory

Fill in the Information to Download Brochure

*mandatory
EMR Global V-Type transformer tap changer mechanism

Fill in the Information to Download Brochure

*mandatory
EMR Global D-Type tap changer assembly for high voltage power transformers

Fill in the Information to Download Brochure

*mandatory

Fill in the Information to Download Brochure

*mandatory

Fill in the Information to Download Brochure

*mandatory